Welcome to Genesys Automation Store

Industrial Automation Product 7 image views

High Frequency Level Sensor RFLS-28 for Liquid Detection

The RFLS-28 high-frequency level sensor is designed for accurate limit level detection in liquids, slurries, and viscous industrial media. Built for reliable tank monitoring, it eliminates false readings caused by foam or residue on the electrode. The sensor supports conductive and non-conductive liquids and works in demanding environments such as chemical processing, food manufacturing, and storage tanks, providing stable level control and dependable process automation.

Category Level
Brand Dinel
Professional support for product selection and quotation requests.

Technical details and application highlights

Review the complete description, feature set, and specification details before sending your inquiry.

The RFLS-28 high-frequency level sensor is engineered for precise limit level detection in demanding industrial applications. Designed for reliable monitoring of liquids, slurries, and paste-like materials, this sensor provides stable performance even in challenging environments where deposits, foam, or viscous media may affect traditional sensors.

Using advanced high-frequency sensing technology, the RFLS-28 ensures accurate switching when the medium reaches a predefined level. It can be installed in tanks, vessels, sumps, or pipelines, making it ideal for industries such as food processing, chemical manufacturing, water treatment, and industrial automation. Its ability to detect both conductive and non-conductive liquids makes it a versatile solution for process control systems.

Key Features

The RFLS-28 sensor offers advanced sensing capabilities for industrial level monitoring.

• Reliable limit level detection for liquids, slurries, and pastes
• Resistant to deposits, foam, and viscous media buildup
• Suitable for conductive and non-conductive liquids
• High sensitivity detection with stable switching behavior
• Adjustable configuration using magnetic pen or setting wire
• Medium recognition capability using advanced sensing logic

This sensor provides consistent measurement even in applications where other level detection technologies may fail.

Design & Functionality

The sensor features a durable stainless steel housing with a sensing electrode engineered for high-frequency signal detection. The robust design enables reliable operation in harsh industrial environments, including chemical processing systems and food production equipment.

High-frequency measurement technology allows the sensor to distinguish the presence or absence of liquid media with exceptional stability. The device also reduces interference caused by material deposits, foam layers, or residues on the electrode surface, ensuring long-term measurement accuracy.

Total Crossed Beams

The RFLS-28 utilizes a highly sensitive detection principle that monitors changes in the electrical properties of surrounding media. This allows precise identification of the liquid level within tanks and containers.

The sensing system reliably detects level thresholds even when the medium contains foam, viscous residue, or adhesive substances that normally interfere with traditional sensors.

Beam Pitch Options

Different mounting variants allow flexible installation depending on the application requirements.

Front thread versions support side mounting for tank walls, while rear thread models enable vertical installation using tubular extensions. This adaptability allows the sensor to be integrated into a wide range of industrial process systems.

Intrinsic Synchronism

The sensor integrates advanced signal processing to maintain stable switching points. The internal electronics synchronize detection signals to prevent interference from surrounding equipment or fluctuating process conditions.

This ensures reliable level detection even in turbulent environments or vessels with mixers and agitation systems.

Operational Advantages

The RFLS-28 offers several advantages for industrial level control systems.

Its ability to detect both conductive and non-conductive liquids allows it to operate across multiple industries. The sensor also reduces maintenance requirements by preventing false switching caused by foam or material buildup.

With high sensitivity, rugged construction, and flexible installation options, the RFLS-28 is a dependable solution for process automation, tank level monitoring, and industrial fluid management.

Parameter

Specification

Product TypeHigh-Frequency Limit Level Sensor
Supply Voltage7 – 34 V DC
Current ConsumptionMax. 5 mA
Output TypePNP (Open Collector)
Maximum Switching Current300 mA
Status Indication2 LED Indicators (Green, Orange)
Protection ClassIP68
Ambient Temperature−40 °C to +80 °C
Maximum OverpressureUp to 100 bar
Process ConnectionG ¾" or NPT ¾" thread
Electrode MaterialPEEK insulated electrode
Housing MaterialStainless Steel (AISI 316L)
Medium Permittivity≥ 1.5
WeightApprox. 0.15 kg
Configuration MethodMagnetic pen or programming wire